n Polarized GlassOutPrePolarized Glass removal

1 Remove 4 screws A M2.5x4 and take the LCD Prism ass'y off upward from the optical unit. 2 Remove each screw B and take the glass off upward. Do not replace the LCD panel separately otherwise it can not obtain proper picture.

00

ModelChassis No

These schematic diagrams and printed wiring board drawings are part of the service manual original for chassis No. ME3-XU4500, MF3-XU4600 models PLC-XU45, PLC-XU46. File with the service manual No. SM5110464-00. All the information of part numbers and values indicated on these diagrams are at the beginning of production. To improve the performance, there may be some differences to the actual set. When you order the service parts, use service parts code mentioned on the parts list in this...

Thermal switch

There is the thermal switch SW902 inside of the projector to prevent the internal temperature from rising abnormally. When the internal temperature reaches near 100 C, turn off the AC main power supply automatically. The thermal switch is not reset to normal automatically even if the internal temperature becomes normal. Reset the thermal switch following procedure. Check the resistance between terminals of thermal switch by using the tester. If it has high impedance, thermal switch may be in...

I

A General B Non flammable Z Low noise T 10ppm oC D 100ppm oC G 350ppm oC Y 1400ppm oC 10 L 2700ppm oC 10 P 3600ppm oC 10 S 4300ppm oC 10 U 25ppm oC E 200ppm oC H 1000ppm oC 10 J 2000ppm oC 10 M 3000ppm oC 10 Q 3900ppm oC 10 V 4500ppm oC 10 C 50ppm oC F 250ppm oC W 1200ppm oC 10 K 2400ppm oC 10 N 3300ppm oC 10 R 4200ppm oC 10 X 8000ppm oC 10 A 0.05 B 0.1 C 0.25 D 0.5 F 1 G 2 J 5 K 10 M 20 P 5-15 Z 0 ohm Rated value, ohms K 1,000, M 1,000,000 WIRE WOUND Wire Wound CERAMIC RES Ceramic FUSIBLE RES...

Color Shading Correction

These initial values are the reference data written from the CPU ROM to memory IC when replaced new memory IC. The adjustment items indicated with are required to readjust following to the Electrical adjustments. Other items should be used with the initial data value.

Lp901

ASSEMBLIED BOARDS ME3-XU4500, PLC-XU45 A 610 292 5609 ASSY,PWB,KEY SW MS6A A 610 299 7330 ASSY,PWB,AV MK8A A 610 299 7347 ASSY,PWB,DVI MK8A A 610 301 0939 ASSY,PWB,POWER MK8A A 610 301 0946 ASSY,PWB,P.F. MK8A A 610 301 0953 ASSY,PWB,LINE FILTER MK8A A 610 301 0960 ASSY,PWB,R C MK8A A 610 304 8925 ASSY,PWB,MAIN ME3A A 610 304 8932 ASSY,PWB,TEMP ME3A OUT OF CIRCUIT BOARDS ME3-XU4500, PLC-XU45 lf901 645 056 9630 UNIT,NOISE FILTER lp900 610 304 5214 COMPL,OPTICAL LAMP-ME3A L901 645 044 6207...

Disassembly Cleaning

Power Supply Str Z2156

Disassembly cleaning method should only be performed when the unit is considerable dirty and cannot be sufficiently cleaned by air spraying alone. Be sure to readjust the optical system after performing disassembly cleaning. 1. Remove the cabinet top and main units following to Mechanical Disassemblies. 2. Remove the optical base top following to Optical Unit Disassemblies. If the LCD panel needs cleaning, remove the LCD panel unit following to LCD panel replacement. 3. Clean the optical parts...

No Power

Fluke Scopemeter 199b Electrical Diagram

The possible causes of No Power are listed below. Please check following and refer to power supply and protection circuits diagram in the figure opposite. 1. Stop the operation of power supply circuit due to detection of abnormality. - Detected the abnormality on the secondary power supply lines. Power failure detection diodes detect an abnormal voltage on the power supply. Check the shortage of secondary circuits, ICs, condensers, etc. - Detected the operation stop of cooling fans. Power...